BIM Services for Data Center

Coordinated, construction-ready models for mission-critical facilities, from white space to central plant.

Service Overview

One model that power, cooling, IT and construction teams can all build from.

One model that power, cooling, IT and construction teams can all build from. Data centers pack more services into less space than almost any other building type. Busways, chilled water mains, CRAH units, fire suppression, cable trays and containment all compete for the same few hundred millimetres above the racks. A single clash found on site can delay commissioning by weeks and push back the date the first rack goes live.

Our BIM team builds detailed, coordinated models of your facility before construction starts. We model architecture, structure and every MEP system to the level of detail your project needs, run clash detection across all trades, and turn the agreed model into shop drawings, prefabrication spools and quantity take-offs.

We work on hyperscale campuses, colocation facilities, enterprise data halls and modular edge sites, both new builds and live-site retrofits. Teams join at concept, design development or pre-construction, and we can hand over an asset-ready model for facility operations once the building is complete.

Data Centers We Model

Every facility type has different constraints. We plan for each one.

Hyperscale Campuses

Multi-building sites with repeatable halls, where model standards and prefab speed matter most.

Colocation Facilities

Flexible white space, cages and suites built in phases as tenants move in.

Enterprise Data Halls

In-house server rooms and data halls inside offices, hospitals, banks and campuses.

Modular & Edge Sites

Containerised and prefabricated units, modeled for factory build and fast site assembly.

AI & High-Density Halls

High rack densities with direct-to-chip or immersion liquid cooling and heavier power loads.

Retrofits & Expansions

Upgrades inside live facilities, planned around equipment that must stay running.

Our Approach

A clear, four-stage process from first drawings to handover.

1

Scope & BIM Execution Plan

Federated models checked in Navisworks for hard and soft clashes, with weekly clash reports and coordination meetings until every trade signs off.

2

Modeling by Discipline

Architecture, structure, electrical, mechanical, plumbing and fire protection are modeled in parallel, each to the agreed level of detail.

3

Coordination & Clash Resolution

Models are federated and checked for clashes. We resolve issues with your engineers and contractors until every system fits and can be maintained.

4

Deliverables & Handover

You receive coordinated models, shop drawings, take-offs and, if required, a COBie-ready model for facility management and operations.

Key Benefits

What a coordinated model changes on a data center project.

Faster time to go-live
Clashes are solved in the model, not on site, so installation and commissioning stay on schedule.
Less rework and waste
Accurate take-offs and coordinated routes reduce material waste and costly site changes.
Ready for prefabrication
LOD 400 models let contractors build skids, racks and pipe spools off site and install them quickly.
Built for uptime
Maintenance clearances and redundant (N+1, 2N) paths are checked in the model before anything is installed.
Easier future expansion
An accurate as-built model makes it simpler to plan new data halls, higher rack densities or liquid cooling.

Deliverables & Level of Development

Choose the detail level that matches your project stage.

LOD Best for What you receive
LOD 200 Concept and feasibility Massing models, space planning and early capacity studies
LOD 300 Design development Accurate sizes and locations of all systems, design coordination, 2D drawings
LOD 350 Pre-construction Supports, hangers and connections between systems, clash-free coordinated models
LOD 400 Fabrication and installation Shop drawings, spool drawings, prefabrication models and quantity take-offs
LOD 500 Handover and operations Field-verified as-built model with asset data (COBie) for facility management

Autodesk Revit

Navisworks Manage

AutoCAD MEP

BIM 360 / ACC

Recap Pro

Dynamo

Synchro 4D

Case Study

Coordinated BIM for a 24 MW Tier III colocation data center

We delivered LOD 400 models of every discipline, full MEP coordination and prefabrication drawings for a two-storey colocation facility built on a fast-track programme.

Client

Global colocation provider

Location

Frankfurt, Germany

Facility size

18,500 m² / 24 MW IT load

Data halls

4 halls, 1,600 racks

Scope

Arch, Structure, MEP, FP — LOD 400

Software

Revit, Navisworks, ACC

Tier rating

Tier III, N+1 cooling, 2N power

Duration

7 months

The challenge

The client needed the first two data halls live in 14 months. Design was still changing when construction started, and five trade contractors were working from separate 2D drawings. The ceiling void above the white space had to fit busways, cable trays, chilled water mains, fire suppression and containment in under 1.2 metres, with clear maintenance access for every critical component.

Our solution

We set up a BIM Execution Plan in the first week and built a federated model of architecture, structure and all MEP systems. Weekly clash detection in Navisworks, with tracked issues and assigned owners, let each trade see and fix problems before they reached site.

Once routes were agreed, we produced LOD 400 shop drawings, pipe spool drawings and electrical skid layouts so the contractor could prefabricate off site. 4D sequencing linked to the model helped plan a phased build, so Halls 1 and 2 could open while Halls 3 and 4 were still under construction.

The outcome

The model was clash-free before installation began in the data halls. Prefabricated assemblies went in faster with almost no site modification, and the client received a COBie-ready as-built model for facility operations at handover.

Our BIM Services

Full-scope modeling and coordination for every system in a data center.

Architectural & Structural Modeling

Data halls, raised floors, plinths, roof plant areas and structural framing modeled to LOD 300–400, including load-bearing zones for heavy equipment.

Electrical & Power Distribution

Utility intake, generators, UPS, switchgear, busways, PDUs, RPPs and cable tray routing, with clearances and maintenance access built in.

MEP-BIM

Mechanical & Cooling Systems

Chillers, CRAH/CRAC units, chilled water piping, in-row and liquid cooling loops, and hot/cold aisle containment, ready for CFD analysis.

Architectural

White Space & Rack Layout

Rack, cabinet and cage layouts with structured cabling, fibre pathways and overhead or underfloor distribution, coordinated with power and cooling.

MEP Coordination & Clash Detection

Federated models checked in Navisworks for hard and soft clashes, with weekly clash reports and coordination meetings until every trade signs off.

Architectural

Shop Drawings & Prefabrication

Fabrication-level LOD 400 models, spool drawings and skid layouts for off-site manufacture of piping, electrical racks and modular units.

4D Scheduling & 5D Cost

Construction sequences linked to the model to plan phased build-outs, plus quantity take-offs for accurate cost estimates and procurement.

Scan to BIM & As-Built Models

Laser scan point clouds turned into accurate as-built models of existing facilities, for retrofits, capacity upgrades and live-site expansions.

Why Choose Us

A BIM partner that understands mission-critical work

Data centers leave no room for error. Our team plans every route, clearance and connection so your facility is built right the first time.

Data center specialists
Our modelers know power redundancy, cooling layouts and containment, not just general building BIM.
All trades in one model
Architecture, structure and every MEP system are coordinated together, so nothing is missed between disciplines.
Fast turnaround
Scalable teams and time-zone overlap let us keep pace with fast-track data center programmes.
Standards you can trust
ISO 19650-aligned workflows, your naming conventions and clear BIM Execution Plans on every project.
Secure and confidential
NDAs, controlled access and secure file sharing protect sensitive facility layouts and client data.
One point of contact
A dedicated BIM coordinator manages your project, reports progress and joins your coordination meetings.
1 +

Scanned Projects Delivered

1 +

Years of BIM Experience

1 +

Qualified BIM Professionals

1 %

Client Satisfaction Rate

Client Feedback

What Project Teams Say About Working With Us

Honest words from the people behind our continued success

4.9 / 5.0

Trusted by 200+ Clients

Popular Questions

Answers to common questions about BIM for data center projects.

What types of data center projects do you support?
We work on hyperscale campuses, colocation facilities, enterprise data halls, modular and edge data centers, and retrofits or capacity upgrades of existing live sites.
Which level of development (LOD) do I need?
LOD 300 suits design coordination. For construction and prefabrication, most contractors need LOD 350–400. LOD 500 is used for handover and facility management. We help you choose based on your stage and contract requirements.
Can you model an existing data center while it is operating?
Yes. We use laser scan data to create accurate as-built models with minimal disruption, then plan upgrades such as new cooling systems or higher-density racks around live equipment.
What inputs do you need to get started?
Design drawings (PDF or CAD), specifications, equipment schedules and your BIM standards, if any. For existing sites, point cloud scans or site access for scanning.
How do you share models and track clashes?
Models are shared on Autodesk Construction Cloud or your common data environment. Clashes are tracked with assigned owners and due dates, and reviewed in regular coordination meetings.

Planning a new data center or an upgrade?

Send us your drawings and we will show you how a coordinated BIM model can protect your schedule.